Multitest plus Pult ME

 

Computer-assisted equipment tester for performing static tests at low and medium pressure on full-face masks, lung-governed demand valves and SCBAs

 

 

 

Multitest plus Pult ME with a dummy head and a mask mounted for testing

Article number:330-615

 

 

Why use Multitest plus Pult ME?

Featuring only four controls, Multitest plus Pult ME makes it easy to efficiently and conveniently carry out all the static tests that need to be performed on full-face masks and lung-governed demand vales. In addition, it can be used for medium-pressure tests.

The tester is equipped with electronic pressure transducers. It can, thus, be connected to a computer, which guarantees an outstanding quality in terms of equipment testing and data documentation. While Multitest plus Pult ME is operated manually, data can be recorded and managed in a computer-assisted manner thanks to the feature-packed MENZL Equipment Management and Testing program. It is, however, also possible to use the tester without a com-puter and record data manually by taking the readings of its pressure gauges. The low-pressure gauge has a zero-offset calibration screw.

Multitest plus Pult ME comes with round-thread connectors for lung-governed demand vales and full-face masks. Adapters (sold separately) are available for all commonly used types of positive-pressure masks and positive-pressure lung-governed demand valves. The required levels of positive and negative pressure as well as the necessary flow rates for opening-pressure tests and closing-pressure tests are supplied by the built-in pump.

Full-face masks are strapped onto an inflatable dummy head for testing in order to guarantee a perfect fit. Two-point (HMC) masks can be tested using special accessories (sold separately) (see below).

 

Multitest plus Pult ME Multitest plus Pult ME: mains switch and power-cord socket Multitest plus Pult ME: lung-governed demand valve attached to equipment connector for testing
Multitest plus Pult ME Power switch and
power-cord inlet
Lung-governed demand valve attached
to equipment connector for testing

Possible tests

  • full-face masks – leak test
  • full-face masks – exhalation-valve opening pressure
  • lung-governed demand valves – leak test
  • lung-governed demand valves – opening pressure
  • lung-governed demand valves – closing pressure
  • SCBAs – static medium pressure
  • chemical protective suits – leak test (accessories required)

Scope of delivery

  • Multitest plus Pult ME
  • dummy head (complete with a filling valve and clamp)
  • mask testing hose (round thread)
  • sealing plug for demand valve hose
  • silicone spray
  • power cord and USB cable
  • MENZL Equipment Management and Testing program
  • operator’s manual

The computer system is NOT included in the scope of delivery. You can order it from us, or you can provide one that meets the system requirements stated by us.

Specifications

dimensions (w x h x d): 420 x 210 x 400 mm
weight: approx. 16 kg
power supply: 230 V; 50 Hz
power consumption: 100 W
low-pressure gauge: ±30 mbar1 (accuracy class 1.6)
low-pressure transducer: ±30 mbar (accuracy 0.5%)
medium-pressure gauge: 0-16 bar (accuracy class 1.0)
medium-pressure transducer: 0-16 bar (accuracy 0.5%)
equipment connector: round thread (EN 148-1)
medium-pressure connector: euro coupling
 

1)

Units for international markets. Units for the Austrian market come with a ±20 mbar low-pressure gauge.

Accessories for equipment testing

Accessories for testing full-face masks

Threaded connector M45x3 330-050
MSA plug-in connector 330-048
MSA plug-in connector AutoMaXX 330-152
Dräger plug-in connector 330-049
Interspiro plug-in connector 330-051
Interspiro Click 330-168
Interspiro Inspire 330-496
Plug-in connector ESA 330-178
Racal plug-in connector 330-564

Accessories for testing two-point helmet masks

Helmet-mask holder for dummy head – Dräger/MSA 330-210
Helmet-mask holder for dummy head – Interspiro 330-522
Helmet-mask testing Implement (standard model) 330-233
MSA docking adapters for helmet-mask testing implement 330-127
Interspiro docking adapters for helmet-mask testing implement 330-128

Accessories for testing lung-governed demand valves (LGDV)

M45x3 330-012
MSA plug-in connector 330-011
MSA plug-in connector AutoMaXX 330-149
Dräger plug-in connector 330-013
Interspiro plug-in connector 330-014
Interspiro Click 330-162
Interspiro Inspire 330-498
Plug-in connector ESA 330-175

Accessories for testing chemical protective suits (CPS)

Testing hose with connection cap for MSA suit valves 330-039
Filling hose with connection cap for MSA suit valves 330-041
Connection cap for Dräger CPSs on request
Connection cap for Koch CPSs on request
Adapter for testing Interspiro CPSs 330-294

Other accessories

Silicone spray for dummy head 330-470
Protective hood for dummy head 340-001
Sealing plug for testing hose 330-605
Hand pump for dummy head 330-527
   
Cylinder pressure gauge for 200-bar and 300-bar cylinders 330-023

MENZL Equipment Management and Testing program 330-004

Barcode scanner, wired (USB) 330-154
Barcode scanner, wireless (USB) 330-221
Barcode labels, back adhesive (pack of 100) 330-219
Barcode labels, front adhesive (pack of 100) 330-220

Replacement parts

Dummy-head rubber part 900-018
Fastening clamp for dummy-head rubber part 1900-032
C-clamp with an eyebolt 3000-003
Push-button valve for dummy-head filling hose 330-115
Dummy-head filling hose complete with push-button valve 330-272
Exhalation-valve sealing cap for MSA Auer normal-pressure masks 264
Sealing nipple for LGDV medium-pressure hose 330-526
Mask testing hose (round thread – round thread 10 mm) 330-200
Gasket for equipment connector 100-063
Countdown timer 330-474

Pressure gauge ±30 mbar

2500-024
Pressure gauge 0-16 bar 70-047